4. SCON-CA


117


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”)

Address Bit

Symbol

Function

Details

Acceleration 16-bit

data -

Deceleration 16-bit

data -

16-bit integer.
Specify the acceleration and deceleration at which to move the
actuator.
The unit is 0.01 G, while the specifiable range is 1 to 300.
(Example) To set 0.30 G, specify “30.”
If a move command is issued by specifying “0” or a value
exceeding the maximum acceleration or maximum
deceleration, an alarm will occur.

4.6 (3)

Push-current
limiting value

16-bit data

-

16-bit integer.
Specify the current-limiting value during push-motion
operation.
The specified range is 0 (0%) to 255 (100%).
The actual specifiable range varies with each actuator. (Refer
to the catalog or operation manual for each actuator.)
If a move command is issued by specifying a value exceeding
the maximum push current value, an alarm will occur.

4.6 (3)

Load current

threshold

16-bit data

-

16-bit integer.
If judgment will be made as to whether or not the load current
exceeded the set value, specify the threshold value for current
using this register.
The specifiable range is 0 (0%) to 255 (100%).
If judgment is not performed, enter “0.”

4.6 (3)

b15

b14

b13

b12

b11

-

Cannot be used.

-

b10 SMOD

Standstill control mode: When the signal is ON, servo control is
performed at in a standstill state.

4.4.7 (28)

b9 ASO1

Stop

Mode 1

b8 ASO0

Stop

Mode 0

Select stop mode while standing by

ASO1

ASO0

Functions

OFF OFF

Disable
(Servo is ON at all times)

OFF ON

Sever turns OFF in time set
in Parameter No. 36

ON OFF

Sever turns OFF in time set
in Parameter No. 37

ON ON

Sever turns OFF in time set
in Parameter No. 38

4.4.7(30)

b7 MOD1

b6 MOD0

Acceleration/deceleration mode:

MOD1 MOD0

Function

OFF OFF Trapezoid

pattern

OFF ON S-motion
ON

OFF

primary delay filter

4.4.7 (29)

b5

b4

-

Cannot be used.

-

PLC output

Control signal 1

b3 INC

Incremental specification:
Absolute position command when the signal is OFF, or
incremental position command when the signal is ON.

4.4.7 (24)

Advertising
This manual is related to the following products: