5. Flow and Commands of Basic MECHA

TROLINK Communication


188

(2) I/O signal assignments for each axis

An I/O signal of each axis consists of 16 words (32 bytes) of I/O addresses.

z Control signals 1 and 2 and status signals are bit ON/OFF signals.

z The target position and current position are both a 2-word (32-bit) binary data. Although values from -999999

to +999999 (unit: 0.01 mm) can be handled by the PLC, set position data within the software stroke range (0
up to the effective stroke length) of the applicable actuator.

z Set a desired positioning band. The positioning band is a 2-word (32-bit) binary data and values from 1 to

+999999 (unit: 0.01 mm) can be handled by the PLC.

z The acceleration/deceleration is a 1-word (16-bit) binary data. Although values from 1 to 300 (unit: 0.01 G) can

be handled by the PLC, set a value not exceeding the maximum acceleration and maximum deceleration of
the applicable actuator.

z The push-current limiting value is a 1-word (16-bit) binary data. Although values from 0 (0%) to 255 (100%)

can be handled by the PLC, set a value within the specifiable range of push-current limiting values of the
applicable actuator (refer to the catalog or operation manual for the actuator).







z Set a desired load current threshold. The load current threshold is a 1-word (16-bit) binary data. Values from 0

(0%) to 255 (100%) can be handled by the PLC. (Refer to the graph of push-current limiting value (upper
graph).)

z The zone boundary+ and zone boundary- are both a 2-word (32-bit) binary data. Although values from

-999999 to +999999 (unit: 0.01 mm) can be handled by the PLC, set values so that the zone boundary-
becomes smaller than the zone boundary+.

z The command current is a 2-word (32-bit) binary data (unit: 1 mA).

z The current position is a 2-word (32-bit) binary data (unit: 0.01 mm/sec).

Positive value: The actuator is moving in the direction opposite home. / Negative value: The actuator is moving
in the direction of home.

z The alarm code is a 1-word (16-bit) binary data.

z The force feedback data is 2-word (32-bit) binary data (unit: 0.01 N).

z The total moving count is a 2-word (32 bits) binary data (unit: times).

z The total moving distance is a 2-word (32 bits) binary data (unit: m).

Set value

Push-current
limiting value