4. SCON-CA


119


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”)

Signal type

Bit

Symbol

Description

Details

Current position

32 bit data

-

32-bit signed integer indicating the current position.
The unit is 0.01 mm.
(Example) Reading: 000003FFH = 1023 (decimal) = 10.23 mm
* If this data is read as a hexadecimal, a negative value is

indicated by a 2’s complement.

4.6 (3)

Command current 32-bit data

-

32-bit integer.
The value of electrical current specified by the present
command is indicated.
The unit is mA.
(Example) Reading: 000003FFH = 1023 (decimal) = 1023 mA

4.6 (3)

Current speed

32-bit data

-

32-bit signed integer.
The current speed is indicated.
Positive value: The actuator is moving in the direction opposite
home.
Negative value: The actuator is moving in the direction of home.
The unit is 0.01 mm/sec.
(Example) Reading: 000003FFH = 1023 (decimal) = 10.23
mm/sec
* If this data is read as a hexadecimal value, a negative value

is indicated by a 2’s complement.

4.6 (3)

Alarm code

16-bit data

-

16-bit integer.
If an alarm occurs, an alarm code will be output.
0 is output when no alarm is present.
For details on alarms, refer to the operation manual for the
controller.

4.6 (3)

Total moving

count

32bits data

-

32-bit integer
(unit: times)

-

Total moving

distance

32bits data

-

32-bit integer
(unit: m)

-

b15

b14

b13

b12

b11

b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

-

Unavailable

-

PLC in

put

Status signal 1

b0 ALML

Light error status:
Turns ON when light alarm (threshold exceeded for number of
movement, etc.) that the operation can be continued with is
issued.
Note: ALM LED would not turn ON with a light error.

4.4.7 (31)