4. SCON-CA


120


Signal type

Bit

Symbol

Description

Details

b15 EMGS

Emergency stop: An emergency stop is being executed when
the signal is ON.

4.4.7 (2)

b14 PWR

Controller ready: The signal turns ON when the controller
becomes ready.

4.4.7 (1)

b13 ZONE2

Zone 2: The signal is ON when the current position is inside the
specified zone.

4.4.7 (12)

b12 ZONE1

Zone 1: The signal is ON when the current position is inside the
specified zone.

4.4.7 (12)

b11 PZONE

Position zone: The signal is ON when the current position is
inside the specified position zone.

4.4.7 (12)

b10 LOAD

Load Output Judgment:
“ON” for Reached “OFF” for Not reached
[Refer to the instruction manual for the controller main body for
more information.]

4.4.7 (26)

b9 TROS

Torque Level:
“ON” for Reached “OFF” for Not Reached
[Refer to the instruction manual for the controller main body for
more information.]

4.4.7 (27)

b8 RMDS

Operation mode: The signal is OFF when the current mode
AUTO, or ON when the current mode is MANU.

4.4.7 (19)

b7 GHMS

Home return in progress: The signal is ON while the home
return is in progress.

4.4.7 (6)

b6 PUSHS

Push-motion operation in progress: The signal is ON while the
push-motion operation is in progress.

4.4.7 (25)

b5 PSFL

Missed load during push-motion operation: The signal turns ON
when the actuator missed the load during push-motion
operation.

4.4.7 (23)

b4

SV

Ready: The signal is ON when the servo is ON.

4.4.7 (5)

b3

ALM

Alarm: The signal turns ON when an alarm occurs.

4.4.7 (3)

b2

MOVE

Moving signal: The signal is ON while the actuator is moving.

4.4.7 (9)

b1 HEND

Home return complete: The signal turns ON when the home
return is completed.

4.4.7 (6)

PLC in

put

Status signal 2

b0 PEND

Positioning complete signal: The signal turns ON when the
positioning is completed.

4.4.7 (10)