background image

3. SCON-CA/CF

A


23

(3) I/O signal assignments

Which signals are assigned to controller I/O ports vary according to the setting of parameter No. 25.
(For details, refer to the operation manual for the controller.)

ACON

Setting of parameter No. 25

Positioning mode

Teaching mode

256-point mode

0 1 2

Category Port No.

Symbol

Signal name

Symbol

Signal name

Symbol

Signal name

0 PC1

PC1

PC1

1 PC2

PC2

PC2

2 PC4

PC4

PC4

3 PC8

PC8

PC8

4 PC16

PC16

PC16

5 PC32

Command position

number

PC32

Command position

number

PC32

6 -

MODE

Teaching mode

command

PC64

7 -

JISL

Jog/inching

switching

PC128

Command position

number

8 -

Cannot be used.

JOG+

+Jog

-

Cannot be used.

9

BKRL

Forced brake release

JOG-

-Jog

BKRL

Forced brake release

10 RMOD Operation

mode RMOD

Operation mode

RMOD

Operation mode

11

HOME

Home return

HOME

Home return

HOME

Home return

12 *STP

Pause

*STP

Pause

*STP

Pause

13 CSTR Positioning

start

CSTR/

PWRT

Positioning start /

Positioning data read

command

CSTR Positioning

start

14 RES

Reset

RES

Reset

RES

Reset

PLC

output

o

ACON

input

15

SON

Servo ON command

SON

Servo ON command

SON

Servo ON command

0 PM1

PM1

PM1

1 PM2

PM2

PM2

2 PM4

PM4

PM4

3 PM8

PM8

PM8

4 PM16

PM16

PM16

5 PM32

Completed position

number

PM32

Completed position

number

PM32

6 MOVE Moving

signal MOVE

Moving signal

PM64

7

ZONE1

Zone 1

MODES Teaching mode signal

PM128

Completed position

number

8

PZONE

Position zone

PZONE

Position zone

PZONE

Position zone

9

RMDS

Operation mode

RMDS

Operation mode

RMDS

Operation mode

10 HEND

Home return

complete

HEND

Home return complete

HEND

Home return complete

11 PEND

Positioning complete

signal

PEND/
WEND

Positioning complete

signal/position data

read complete

PEND

Positioning complete

signal

12

SV

Operation ready

SV

Operation ready

SV

Operation ready

13 *EMGS Emergency

stop *EMGS

Emergency stop

*EMGS

Emergency stop

14 *ALM

Alarm

*ALM

Alarm

*ALM

Alarm

ACON

output

o

PLC

input

15

-

Cannot be used.

-

Cannot be used.

-

Cannot be used.

* indicates a signal that is normally ON.
The signals denoted by “Cannot be used” are not controlled. (ON/OFF statuses of these signals are