5. Flow and Commands of Basic MECHA

TROLINK Communication


217


(3) I/O signal assignments

For the signal assignments in each PIO pattern, refer to (3), “I/O signal assignments” under 5.4.2, “Remote I/O
Mode.”

The signal assignments for command-current and current-position read functions are shown below.

Signal type

Bit

Symbol

Description

Details

Current position

32-bit data -

32-bit signed integer indicating the current position.
The unit is 0.01 mm.
(Example) Reading: 000003FFH = 1023 (decimal) = 10.23 mm
* If this data is read as a hexadecimal, a negative value is

indicated by a 2’s complement.

-

PLC in

put

Force feedback

data

32-bit data -

32-bit signed integer indicating the current position.
The current load cell reading is indicated.
The unit is 0.01 N.
* If this data is read as a hexadecimal, a negative value is

indicated by a 2’s complement.

-