IAI America PCON-CFA User Manual

Page 181

Advertising
background image

5. Flow and Commands of Basic MECHA

TROLINK Communication


175


5.4.3 Position/Simple Direct Mode (Number of Occupied Bytes: 8)


In this mode, the actuator is operated by specifying position numbers. You can select whether to set the target
position directly as a value or use a value registered in the position data table, by switching a control signal
(PMOD signal).
For all data other than the target position, such as speed, acceleration/deceleration and positioning band, values
in the controller’s position table are used. Set desired position data by referring to the operation manual for the
controller.
Up to 768 position data points can be set.
The key functions that are available on Actuators controllable in this mode are shown in the table below.

Actuator function

{: Direct control

': Indirect control

x: Invalid

Remarks

Home return operation

{

Positioning operation

{

Speed & acceleration/deceleration setting

'

Pitch feed (inching)

'

Push-motion operation

'

Speed change during movement

'

Operation at different acceleration and deceleration

'

Position data must

be set

Pause

{

Zone signal output

'

Position data or

parameters

PIO pattern selection

x


(1) PLC address configuration (* n indicates the initial input/output address for each axis.)

Parameter

No. 84

SCON-CA input

register

PLC output address

SCON-CA output

register

PLC input address

n+0 n+0

Target position

n+1

Current position

n+1

Specified position

number

n+2

Completed position

number

(simple alarm code)

n+2

1

Control signal

n+3

Status signal

n+3

(Note) Pay attention to use of duplicate addresses.