Teledyne LeCroy BTTracer_Trainer - BTTracer Users Manual User Manual

Page 100

Advertising
background image

90

BTTracer Protocol Analyzer User’s Manual

CATC

SW Version 2.20

Timeout (0-80 secs)

Default value for Inquiry Timeout is 20 seconds.

Correlation Value (33-64)

This value tells BTTracer how many bits in the sync word of each received
packet must be matched in order for BTTracer to consider the packet valid
and start recording.

This value specifies how long BTTracer should perform the Inquiry process
for the General (unlimited) and Dedicated (limited) recording modes. After
the specified time has elapsed, BTTracer will illuminate the trigger light on
the front of the analyzer.

BT Neighborhood

These options configure how the BT Neighborhood command behaves. BT
Neighborhood is a utility that performs an Inquiry and then lists the local
devices that it discovered.

Use Default settings -- Sets the analyzer to record a General

Inquiry with an Inquiry Timeout of 11 seconds.

Match 'Inquiry' Recording Settings -- Sets the analyzer to use

the settings you chose above under Hop Sequence, Inquiry Type,
and Additional Settings.

Advertising