background image

43

BTTracer Protocol Analyzer User’s Manual

CATC

SW Version 2.20

4

Analyzer is recording (only channel 1 is present).

5

Analyzer is synchronized to a piconet with the master device that has
BD_Address 0083716355E.

6

Analyzer is connected to the host machine, but is not performing a thing.

7

Analyzer is connected to the host machine and is powering up.

8

Analyzer is recording on both channel 1 and channel 2. Channel 1 is capturing
the traffic of the piconet with master device that has BD_Address
0083716355E while channel 2 capturing the traffic of the piconet with master
device that has BD_Address 0083713333E.

9

Analyzer is recording on channel 1 the traffic of the piconet with master device
that has BD_Address 0083716355E while channel 2 is trying to sync to the
piconet with master device that has BD_Address 0083713333E.

10

Analyzer is synchronized on channel 1 to the piconet with the master device
that has BD_Address 0083716355E. Channel 2 is in Idle mode.

11

Analyzer is uploading the recorded traffic from channel 1. Channel 2 is in Idle
mode.

12

Analyzer is recording on channel 1 the traffic of the piconet with master device
that has BD_Address 0083716355E while channel 2 is in Idle mode.

13

Analyzer is trying to synchronize on channel 1 to the piconet with the master
device that has BD_Address 0083716355E while channel 2 is in Idle mode.

14

Analyzer is performing an inquiry. In this case channel 2 is always in idle
mode.

15

Analyzer is in idle mode Analyzer is

16

Analyzer is powering up (both channels are present).

As recording progresses, the Progress Indicator changes to reflect the
recording progress graphically:

In the Progress Indicator, a black vertical line illustrates the location of the
Trigger Position you selected in Recording Options.

Pre-Trigger progress is displayed in the field to the left of the Trigger

Position in the before-Trigger color specified in the Display Options.

When the Trigger Position is reached, the progress indicator wiggles as it

waits for the trigger.

After the trigger occurs, the field to the right of the Trigger Position fills

in the post-Trigger color specified in the Display Options.

When recording is complete, the upper half of the progress indicator fills

in white, indicating the progress of the data upload to the host computer.

You should be aware of two exceptional conditions:

If a Trigger Event occurs during the before-Trigger recording, the
before-Trigger color changes to the after-Trigger color to indicate that not all
the expected data was recorded pre-Trigger.