Chapter 10: Recording Options

USB Protocol Suite User Manual

270

LeCroy Corporation

Packets

You must assign a packet, event, or logical expression to a counter and/or timer.

Using a Counter

To use a counter:

Step 1 Click an event to display an arrow.

Step 2 Click a counter. This causes the counter to attach itself to the bottom of the event.

An arrow automatically connects the counter to the Trigger button.

Note: For Timers, do NOT use a timer as the first event in a sequence, since this

first “event” will be the start of recording, and this is not a precise or
predictable point in time from which to start timing. Use timers only AFTER
the first event.

Setting a Counter

To set a counter:

Step 1 Open the Recording Rules page, select an event, and drag it to the Global State

or Sequence cell.

Step 2 Counts can only be set on a per channel basis, so press the Up or Down channel

buttons to select the channel on which the count is performed.

Step 3 Right-click the selected event and select Add Counter from the menu to open

the Properties dialog.

Step 4 In the text box to the right of the label Count, enter a value. Make sure the

checkbox to the left of the word Count is checked.

Step 5 Click the X in the top right corner of the dialog box to close the dialog. A counter

button should appear just below your selected event.

Changing a Counter Value

To change the counter value:

Step 1 Click the small blue dot in the upper-left corner of the counter button to display a

menu.

Step 2 Select Change Counter Value.

Step 3 Enter a new value in the pop-up dialog box. The new value appears in the

counter button.