3 setting up the analyzer - ethernet connection – Teledyne LeCroy USBTracer_Trainer - Users Manual User Manual

Page 66

Advertising
background image

Chapter 3: Installation

USB Protocol Suite User Manual

52

LeCroy Corporation

Step 6 Follow the Microsoft

®

Windows

®

on-screen Plug-and-Play instructions for the

automatic installation of the Analyzer as a USB device on your analyzing PC (the
required USB files are included on the Installation CD).

Step 7 Click Finish when you see the message that says “Windows has finished

installing the software that your new hardware requires” and the driver files have
been installed in your PC.

Step 8 Check Analyzer setup in the “Application Startup” section (See “Application

Startup” on page 56).

Warning! Do not change from USB to Ethernet, or back, without power cycling the

Analyzer.

3.3 Setting Up the Analyzer - Ethernet Connection

To set up an Analyzer using an Ethernet connection:

Step 1 Connect the provided AC power cord to the rear of the Voyager M3 and to a

100-volt to 240-volt, 50-Hz to 60-Hz, 100-W power outlet.

Note: The Analyzer is capable of supporting supply voltages between 100 volts

and 240 volts, 50 Hz or 60 Hz, thus supporting all supply voltages around the
world.

Step 2 Insert the Installation CD.

Step 3 To use a DHCP network, make sure that the PC connects to a DHCP network,

then connect the Ethernet port on the Analyzer to the DHCP network.

Note: If the DHCP network uses a Firewall, you must set the Firewall to allow the
Analyzer device on the network.

Note: Direct connection from the Ethernet port on the PC to the Ethernet port on
the Analyzer is supported in this release. See “IP Settings (Voyager only)” on
page 58.

Step 4 Turn on the power switch.

Note: At power-on, the Analyzer initializes itself in approximately ten seconds and

performs an exhaustive self-diagnostic that lasts about five seconds. If the
diagnostics fail, call LeCroy.

Step 5 Complete Analyzer setup in the “Application Startup” section (See “Application

Startup” on page 56).

Warning! Do not change from USB to Ethernet, or back, without power cycling the

Analyzer.