Teledyne LeCroy USBTracer_Trainer - Users Manual User Manual

Page 37

Advertising
background image

USB Protocol Suite User Manual

Chapter 1: Overview

LeCroy Corporation

23

Recording Options

Versatile triggering: bit-wise value and mask data patterns up to sixteen bytes wide
for Setup transactions and data packets

Triggering on new High-speed PIDs and split transaction special tokens (ERR,
SPLIT, PING, NYET, DATA2, and MDATA) (2.0)

CATC Trace display and enumeration of High-Speed Micro Frames (2.0)

Three forms of triggering: Snapshot, Manual, and Event

Transaction sequencer: Allows triggering on a token qualified by a data pattern
and/or specific handshake, or can filter transactions (for example, NAK’d
transactions) (2.0)

Advanced triggering with event counting and sequencing

Dedicated trigger for recording input and output used to interface to external test
equipment

Triggering on multiple error conditions: PID bad, bit stuffing bad, CRC bad,
end-of-packet bad, babble, activity loss, frame length violation, time-out or
turn-around violation, data toggle violation, Token, Bus Conditions, Data Length,
and excessive empty frames (2.0)

Real-time traffic capture filtering and data packet truncation variable up to 256 bytes
(2.0)

Adjustable buffer size from 0.4 MB to 2 GB

Idle filtering (3.0)