USB Protocol Suite User Manual

Chapter 3: Installation

LeCroy Corporation

63

To add a device, click Add to display the USB3 Device -> Analyzer ->
Host Signal Parameter Profiles dialog.

The dialog allows you to Set Device “Current” or Read from Analyzer.

The dialog allows you to Set Host “Current” or Apply to Analyzer.

You can enter Device to Analyzer Signal Settings:

Device Name

Device Cable ID

Input Signal Equalization (ISE) Settings: Short, medium and long time
constant (Current, Off, Minimum, Moderate, or Maximum)

Pre-Emphasis Settings: Short and long time level (0 to 15) and
short and long time decay (0 to 7)

Output Power Level: Current, or 213 mV to 1294 mV

You can enter Host to Analyzer Signal Settings:

Host Name

Host Cable ID

Input Signal Equalization (ISE) Settings: Short, medium and long time
constant (Current, Off, Minimum, Moderate, or Maximum)

Pre-Emphasis Settings: Short and long time level (0 to 15) and
short and long time decay (0 to 7)

Output Power Level: Current, or 213 mV to 1294 mV

You can also Load the default settings or Load the last applied settings.