1 pin-outs for the data in/out connector, 2 prototype rework area, 3 pc connection – Teledyne LeCroy USBTracer_Trainer - Users Manual User Manual

Page 60

Advertising
background image

Chapter 2: General Description

USB Protocol Suite User Manual

46

LeCroy Corporation

2.17.1 Pin-Outs for the Data In/Out Connector

Table 2 lists the pin-out and signal descriptions for the Data In/Out connector on a cable
that connects to the Breakout Board.

Table 2

Data In/Out Connector – Pin-Out

Note:

(*)

Pins 2 and 3 have the same function: they allow external signals to be

used to cause triggering or recording. Pins 4 and 5 are used to transmit
output signals.

2.17.2 Prototype Rework Area

The Breakout Board contains a prototype rework area for making custom circuits for rapid
development. The area consists of plated-through holes, 20 columns wide by 27 rows
long. The top row of holes connects to GND, and the bottom row connects to +5 V. The
remaining holes are not connected. Use the rework area to insert custom components
and wire-wrap their respective signal, power, and ground pins.

2.17.3 PC Connection

Use the LONGEST (6-foot/2-meter) of the five USB cables provided to connect the host
computer to the Analyzer box.

Pin

Signal Name

Signal Description

1

+5V

+5 Volts, 250mA DC source

2

TRG IN

(*) Trigger Input

3

GP IN

(*) General Purpose Input

4

TRG OUT

(*) Trigger Output

5

GP OUT

(*) General Purpose Output

6

GND

Ground

7

GND

Ground

8

GND

Ground

9

GND

Ground

Advertising