Advanced Waveform Editing
This example edits a sine signal waveform (amplitude 5 V, frequency 10
kHz, duration 300 µs), concatenated to a triangular signal (amplitude 6 V,
frequency 20 kHz, duration 800 µs). The following steps demonstrate the
procedure.
1. Click the Add Advanced Waveform button to open the Waveform
Editor dialog box.
2. Select Component1 of Segment1, choose sine wave in the
component type, set its length to 300 µs, and 3 cycles in the
Parameters window. Now, set the amplitude to 5 V.