Network Performance Analyzer Reference

8

Network Tools

Agilent FrameScope 350 User’s Manual

207

The operator may change any of the following properties of the
traffic being generated:

Frame Length

The number of bytes in the frame, including the

FCS. This number ranges from 64-1518 unless long or short
frames are specified. If the Short Frames box is checked, the
frame size ranges from 40-63. If the Long Frames box is
checked, the frame size ranges from 1519-5000.

Frame Rate

The rate at which frames are transmitted by the

FrameScope. Changing the Frame Rate causes the Utilization to
be recalculated.

Utilization

The percent of the Ethernet bandwidth which the

FrameScope should fill up. This value ranges from 0 which
causes no frames to be transmitted to 100 which causes the
FrameScope to completely load the network connection.
Changing the Utilization causes the Frame Rate to be
recalculated.

# Frames or Continuous

Specifies the number of frames the

FrameScope should generate when the Start button is pressed.
If Continuous is selected, the FrameScope begins generating
frames when the Start button is pressed and does not stop until
the Stop button is pressed or the Traffic Generator tool is
exited.

Errors

Frames with errors may be generated. The error types

include CRC error, short frame or long frame.

Frame Type

802.3/802.2

Ethernet/IP

SNAP/IP

Ethernet/IPX

802.3/IPX

802.2/IPX

SNAP/IPX

Source MAC

Choices include this FrameScope’s MAC or

simulate multiple (10, 100 or 200) stations. The simulated MACs
use the values 00-0C-65-01-00-XX where XX increments from 01
to C8 (hex).