Fiber smartprobe, Specifications – Agilent Technologies N2610A User Manual

Page 238

Advertising
background image

230

Agilent FrameScope 350 User’s Manual

9

Specifications

Fiber SmartProbe+

Fiber SmartProbe

+

General

FiberSmartProbe+850nm, Fiber SmartProbe+ 1300nm

Fiber SmartProbe+ 1310nm, Fiber SmartProbe+ 1550nm

Size

2.4” x 1.6” x 0.8”
(6.0 cm x 4.0 cm x 2.5 cm)

2.4” x 1.6” x 0.8”
(6.0 cm x 4.0 cm x 2.5 cm)

Optical Connectors

ST® x 2

SC x 2

Power Source

Draws power from WireScope 155 or
DualRemote 155 via intelligent test port interface

Draws power from WireScope 155 or
DualRemote 155 via intelligent test port interface

Operating Temperature

0

o

to 40

o

C

0

o

to 40

o

C

Storage Temperature

- 10

o

to 55

o

C

- 10

o

to 55

o

C

Operating Humidity

10 to 90% non-condensing

10 to 90% non-condensing

Maximum Relative Humidity

80% for temperatures up to 31 C, decreasing
linearly to 50% relative humidity at 40 C

80% for temperatures up to 31 C, decreasing
linearly to 50% relative humidity at 40 C

Altitude

Up to 2000 meters

Up to 2000 meters

Detector

FiberSmartProbe+850nm, Fiber SmartProbe+ 1300nm

Fiber SmartProbe+ 1310nm, Fiber SmartProbe+ 1550nm

Receive Wavelengths

850 and 1300nm

1310nm and 1550nm

Measurement Accuracy

+/-0.2dB @ -20dBm

+/-0.2dB @ -20dBm

Dynamic Range

0 to –40 dBm

0 to –40 dBm

Detector Type

Germanium

Germanium

Transmitter

FiberSmartProbe+850nm, Fiber SmartProbe+ 1300nm

Fiber SmartProbe+ 1310nm, Fiber SmartProbe+ 1550nm

Power Output

(into 62.5/125 multimode fiber)
-10dBm (850nm), -15dBm (1300nm)

(into 9/125 singlemode fiber)
-3 dBm (1310nm and 1550nm)

Source Type

LED

Stabilized Class 1 LASER

2

product in accordance

with EN 60825.1 and FDA 21 CFR 1040.10.

Center Wavelength

1310nm +/- 30nm, 1550nm +/- 30nm

Spectral Bandwidth (RMS)

< 5nm

Stability

N/A

+/- 0.1dB, 1Hr. @ 25 C

Stabilization Time

N/A

< 5 min.

Cable Length

FiberSmartProbe+850nm, Fiber SmartProbe+ 1300nm

Fiber SmartProbe+ 1310nm, Fiber SmartProbe+ 1550nm

Accuracy (whichever is greater)

+/- 4% or +/- 1.5 meters

+/- 4% or +/- 1.5 meters

Resolution

+/- 1.5 meters

+/- 1.5 meters

Distance

1

Range

0 – 4 km for 3.75 dB/km @ 850nm
0 – 10 km for 1.50 dB/km @ 1300nm

0 – 50 km for 0.5dB/km @ 1310nm and 1550nm

Propagation Delay

FiberSmartProbe+850nm, Fiber SmartProbe+ 1300nm

Fiber SmartProbe+ 1310nm, Fiber SmartProbe+ 1550nm

Accuracy (whichever is greater)

+/- 4% or +/- 6 nanoseconds

+/- 4% or +/- 6 nanoseconds

Resolution

+/- 6 nanoseconds

+/- 6 nanoseconds

Range

0 – 300 microseconds

0 – 300 microseconds

1

Assumes double-ended configuration with –15dB maximum multimode

link loss and 25dB maximum singlemode link loss. Divide by two for
single-ended configuration.

2

For safety the transmitter should never be viewed directly with the naked eye, a lens, or

magnifying device.

KLASSE 1 LASER PRODUKT

ST is a registered trademark of AT&T