Characteristics

Table 20 11612V Option K11/K21 Bias Network Characteristics

Parameter

11612V Option K11

11612V Option K21

Test port

Port 1

Port 2

Frequency range

45 MHz to 50 GHz

45 MHz to 50 GHz

Test port connector

2.4 mm

2.4 mm

Maximum current

0.5 amps

0.5 amps

Maximum voltage

40 volts

40 volts

Maximum RF power

2 watts (+33 dBm)

2 watts (+33 dBm)

Height

50 mm (2 inches)

50 mm (2 inches)

Width

105 mm (3.5 inches)

105 mm (3.5 inches)

Depth

70 mm (2.75 inches)

70 mm (2.75 inches)

Net weight

370 grams (0.8 pounds)

370 grams (0.8 pounds)

C A U T I O N

Do not exceed the maximum ratings of the bias networks. Failure to
comply can result in severe damage.