Measure mode settings – Spectra Precision Survey Pro CE v3.60 GPS User Manual User Manual

Page 103

Advertising
background image

GPS Reference Manual

8

Measure Mode Settings

-RE 6HWWLQJV 0HDVXUH 0RGH



The Measure Mode card is used to configure the RTK data collection
settings.

Receiver Dynamics

: is where you control the

receiver dynamics for point occupations.

Static on occupy:

On starting a point

occupation, receiver is put in static
mode where it calculates position
assuming no motion and applies
advanced averaging techniques for the
most precise solution.

Dynamic always

: Receiver is left in

dynamic mode for all point occupations.

Store GPS Raw Data

: is where you set the mode for raw data

storage. The following options are available:

Lat, Lng, Ht (EP)

: stores just a geodetic position (EP) record

in the Survey Pro .RAW file for each measurement.

EP + Bl,CV

: stores EP, the RTK base line measurement (BL)

and associated covariance matrix (CV) in the Survey Pro
.RAW file for each measurement.

Note: Ashtech receivers do not store base lines (BL) and covariance
(CV) records in the Survey Pro raw data file. Instead, they use a
separate Ashtech format .OBN file to store this information. The
user interface for Ashtech receivers will show OBN in place of BL,CV.

EP + Bl,CV + Rx Raw

: stores EP, and the base line and

covariance matrix (BL,CV) in the Survey Pro .RAW file. Also
sends the station and antenna information to the receiver’s
internal raw data file for post processing.

EP + Rx Raw

: stores EP in the Survey Pro .RAW file. Also

sends the station and antenna information to the receiver’s
internal raw data file for post processing.

Advertising