38

8. Tap

6ROYH /RFDOL]DWLRQ to open the Solve Localization wizard.

Note: If you are using localization for the vertical transform mode,
then the next screen will look like the illustration below. If you are
using ellipsoid heights, then the vertical column will be missing.

9. In the list box, control points collected

will be identified with an

H

and/or

V

.

Points marked

H

will be used to solve

horizontal localization. Points marked
with a

V

will be used to solve vertical

localization. You can select or deselect
any point by highlighting that point and
then: tap the H and/or V column beside
that point; press H and/or V on the
keyboard.

Note: If your base was set up on a known point, that point is an
eligible control point. If your base was set up on a new point, then it
is not visible on the control point list.

10. If you wish to hold the scale of the GPS measurements, but you

want the localization adjustment to correct for a rotation, check
the

Solve Rotation Only

control in the

Fix H Scale to 1.0

box.

11. Double check the selection of control points and tap

6ROYH !. The

localization parameters are computed using the selected control
points, and the next screen is opened with solution RMS values.


12. For both horizontal and vertical, the solution type and RMS value

from the control points are displayed. The solution type will be
one of:

Advertising