Segment data – West Control Solutions Pro-EC44 User Manual

Page 207

Advertising
background image

Pro-EC44 2-Loop Graphical Profile Controller & Recorder

Pro-EC44 Product Manual - 59540-1 October 2013

Page 200

Auto Hold Type Loop 2 High Byte

A/R

A/R

0 = Auto-Hold Off, 1 = Hold above SP, 2 = Hold
below SP,3 - Hold above and below SP

Auto Hold Type Loop 2 Low Byte

A/R

A/R

Auto Hold Value Loop 2 (Byte 4 - High)

A/R

(Floating

point

number)

The distance loop 2 can be way from setpoint

before Auto-Hold activates.

(Always 0 when profile only controls a single

loop)

Auto Hold Value Loop 2 (Byte 3)

Auto Hold Value Loop 2 (Byte 2)

Auto Hold Value Loop 2 (Byte 1 - Low)

CRC High Byte

A/R

A/R

CRC Low Byte

A/R

A/R

Segment Data

The Segment Data is included in the response to a Read Segment request. It is provided in
two parts (Segment Info A and B).
The meaning of the data contained in Segment Info A and B depends on the type of segment
it relates to. Null is shown for unused data, this can be any value.

Segment Type

Segment Info

Description

A

B

Ramp Time

Time

Target
setpoint

Ramp to the target setpoint “B” in the time “A”

Ramp Rate

Ramp rate

Target
setpoint

Ramp to the target setpoint “B” at the ramp
rate “A”

Step

Null (0)

Target
setpoint

Step to a target setpoint “B”

Dwell

Dwell time

Null (0)

Stay at the current setpoint for time “A”

Hold

0 = Operator Null (0)

Wait for the operator to release the hold or
Digital Input

1 = Time of
day

Start Time

Wait until time of the day “B” in seconds since
midnight (recorder only).

Loop

Number of
times to
repeat 1 to
9999

Segment
number

Loop to the specified segment number “B”
from this point. Repeat this “A” times. Only
segments below the current segment can be
entered. Two loops must not cross each other.

Join

Null (0)

Profile
number

On completion of this profile run profile “B”

End

0 = Control
off

Null (0)

Turn off all control outputs.

1 = Maintain
profile
setpoint

Null (0)

Stay at the final setpoint of the profile

2 = Use
controller
setpoint

Null (0)

Use the active controller setpoint.

Repeat Sequence Then End

0 = Outputs
off

Number of
times to
repeat
sequence

Repeat the profile sequence number “B” times,
then turn off the control outputs

1 = Maintain
profile
setpoint

Repeat the profile sequence number “B” times,
then hold the last profile setpoint.

2 = Use
controller
setpoint

Repeat the profile sequence number “B” times,
then use the active controller setpoint.