Pro-EC44 2-Loop Graphical Profile Controller & Recorder

Pro-EC44 Product Manual - 59540-1 October 2013

Page 59

Activities To Record

Multiple process events can be recorded from: Alarm n Status (n = 1 to 7)

or Unit turned Off/On.

Note: If an alarm changes state between samples, this will also
be recorded using extra memory. The remaining recording time
is reduced accordingly.

Profiler Events To
Record

The Profiler Event n Status can be recorded (n = 1 to 5).

Note: If a profile event changes state between samples, this will
also be recorded using extra memory. The remaining recording
time is reduced accordingly.

CLOCK CONFIGURATION SUB-MENU SCREENS

Date Format

w The format used for all displayed dates: dd/mm/yyyy (Day / Month / Year)

or mm/dd/yyyy (Month / Day / Year).

Recorder versions only.

Set Date

w Set the internal clock Date

– Entered in the format defined by Date Format

screen.

Recorder versions only.

Set Time

w Set the internal clock Time. - In hh:mm:ss (Hours : Minutes : Seconds)

format.

Recorder versions only.

Note: Clock settings cannot be changed when the data recorder is active.

DISPLAY CONFIGURATION SUB-MENU SCREENS

Language

Select English or the alternate local language. The alternate language is

selected at time of order, but can be changed later using the PC software.

Enable Custom
Display Mode

Enables/disables the Custom Operation Mode, if configured. The screens

seen in this mode are configured using the PC configuration software.

Read Only Operation
Mode?

Allows Operation Mode to be Read/Write or Read-Only where screens can

be seen but the values cannot be changed.

Display Colour

From: Red only; Green only; Red to Green on Alarm or Green to Red on

Alarm; Red to Green if Output Latched or Green to Red if Output Latched.

Invert Display

Standard or Inverted display image.

Display Contrast

Screen contrast (10 and 100) to improve clarity. 100 = maximum contrast.

Loop 1 Trend
Sample Interval

The Interval between the displayed values on the loop 1 trend graph.

From: Every 1; 2; 5; 10; 15; 30 Seconds, or 1; 2; 5; 10; 15; 30 Minutes.
- Independent from the loop 2 trend graph and data recorder sample rates.

Loop 1 Trend View
Mode

The data to display on the loop 1 trend graph. From: Process Value only,

PV (solid) & SP (dotted) at sample time, or the Max & Min PV between
samples (candle-stick graph). Alarm active indication is always shown at
the top of graph
.

Loop 2 Trend
Sample Interval

The Interval between the displayed values on the loop 2 trend graph.

From: Every 1; 2; 5; 10; 15; 30 Seconds, or 1; 2; 5; 10; 15; 30 Minutes.
- Independent from the loop 1 trend graph and data recorder sample rates.

Loop 2 Trend View
Mode

The data to display on the loop 1 trend graph. From: Process Value only,

PV (solid) & SP (dotted) at sample time, or the Max & Min PV between
samples (candle-stick graph). Alarm active indication is always shown at
the top of graph
.

Operator Visibility

Extra parameters can be made visible/adjustable in Operation Mode from:

Profile Control; Recorder Start/Stop; Recorder Status; Loop 1 & 2 Setpoint
Select; Loop 1 & 2 Auto/Manual Select; Loop 1 & 2 Control Select; Loop 1
& 2 Trend View; Loop 1 & 2 Setpoint Ramp Rate.

See

◘ in Operator Mode lists.