Messages List

ERROR(timeout):
socket
type=(IMAGE/
EVENT/
COMMAND),
cameraserver=(<ho
st>:<port>)

A timeout occurred while waiting for a
response from the specified camera
server. This normally occurs when the
camera server is offline.
IMAGE == Process of getting image
EVENT == Process of getting camera
server status implemented by GetNotice
COMMAND == Camera server
operation/configuration change
command process

Check to ensure that the camera server
is on and connected to the network. If a
proxy server is configured using the
Storage Server Configuration tool, check
to ensure that the proxy server is
running.

ERROR(connect):
socket
type=(IMAGE/
EVENT/
COMMAND),
cameraserver=(<ho
st>:<port>)
win32_error=(<Wins
ock error code>:
<error message>)

An error occurred when connecting to
the specified camera server.
IMAGE == Process of getting image
EVENT == Process of getting camera
server status implemented by GetNotice
COMMAND == Camera server
operation/configuration change
command process
* same applies for "ERROR
(WSAConnect)".

See the corresponding Winsock error
code in "Error Codes in Log File" (

 P. 9-

31).

ERROR(http):
socket
type=(IMAGE/
EVENT/
COMMAND),
cameraserver=(<ho
st>:<port>)
http_status=(<HTTP
error code>)

An HTTP error occurred when
connecting to the camera server.
IMAGE == Process of getting image
EVENT == Process of getting camera
server status implemented by GetNotice
COMMAND == Camera server
operation/configuration change
command process

See the corresponding HTTP error code
in "Error Codes in Log File" (

 P. 9-31).

Failed to write
camera
configuration file

Cannot overwrite the camera server
configuration file. The setting changes
conducted after the recording engine
started cannot be saved.

Check to ensure that you have the write
privilege for the LocalSystem account in
the VK-64/VK-16 configuration directory.

ERROR: Out of
memory -- please
check configuration
of this PC

Failed to reserve memory in the
recording engine since the system
memory is under a heavy load because
unprocessed frames continued to
increase. An application error will occur
in a few seconds and the Storage Server
functions will stop.

Reduce the system load using the
following methods.
1. Reduce the amount of data to record

(For example, lower the resolution or
frame rate).

2. Install an additional hard disk.
3. Implement an action such as

upgrading the CPU, or increasing
memory or existing hard disk space.