Event log entries – HP Integrated Lights-Out User Manual

Page 188

Advertising
background image

Troubleshooting iLO 2 188

LED indicator

POST code

(activity

completed)

Description

Failure indicated

None

Start C Run time
initialization.

4, 3, and 2

0e

Main() has received control. Main self-test failed.

Varies

Varies

Each subsystem may self-

test.

4, 3, 2, and 1

0f

Start ThreadX.

RTOS startup failed.

None

00

Main_init() completed.

Subsystem startup failed.

HB and 7

Flashes as the iLO 2
processor executes firmware

code. It does not change the
value of the lower six LEDs.

The iLO 2 microprocessor firmware includes code that makes consistency checks. If any of these checks
fail, the microprocessor executes the FEH. The FEH presents information using the iLO 2 POST LED

indicators. The FEH codes are distinguished by the alternating flashing pattern of the number 99 plus the

remainder of the error code.

FEH code

Consistency check

Explanation

9902

TXAPICHK

An RTOS function was called with an inappropriate
value or from an inappropriate caller.

9903

TXCONTEXT

The saved context of one or more threads has been

corrupted.

9905

TRAP

A stack probe failed, the return address is invalid,
or an illegal trap instruction has been detected.

9966

NMIWR

An unexpected write to low memory has occurred.

99C1

CHKNULL

The reset vector has been modified.

Event log entries

Event log display

Event log explanation

Server power failed

Displays when the server power fails.

Browser login: IP address

Displays the IP address for the browser that logged
in.

Server power restored

Displays when the server power is restored.

Browser logout: IP address

Displays the IP address for the browser that logged

out.

Server reset

Displays when the server is reset.

Failed Browser login – IP Address: IP address

Displays when a browser login fails.