Inability to access ilo 2 using telnet, Inability to connect to the ilo 2 diagnostic port, Inability to access the login page – HP Integrated Lights-Out User Manual

Page 194

Advertising
background image

Troubleshooting iLO 2 194

iLO 2 RBSU. In this case, the iLO 2 RBSU will be unavailable or the iLO 2 Option ROM code will be

skipped altogether. If this happens, reset the server a second time. To avoid this issue, wait a few seconds
before resetting the server after resetting the iLO 2 processor.

Inability to access the login page

If you cannot access the login page, you must verify the SSL encryption level of your browser is set to 128
bits. The SSL encryption level in iLO 2 is set to 128 bits and cannot be changed. The browser and iLO 2

encryption levels must be the same.

Inability to access iLO 2 using telnet

If you cannot access iLO 2 using telnet, you must verify the Remote Console Port Configuration and

Remote Console Data Encryption on the Global Settings screen. If Remote Console Port Configuration is

set to Automatic, the Remote Console applet enables port 23, starts a session, and then closes port 23

when the session is completed. Telnet cannot automatically enable port 23, so it fails.

Inability to access virtual media or graphical remote console

Virtual media and graphical Remote Console are only enabled by licensing the optional iLO Advanced

Pack. A message is displayed to inform the user that the features are not available without a license.
Although up to 10 users are allowed to log into iLO 2, only one user can access the remote console. A

warning message is displayed indicating that the Remote Console is already in use.

Inability to connect to iLO 2 after changing network settings

Verify that both sides of the connection, the NIC and the switch, have the same settings for transceiver

speed autoselect, speed, and duplex. For example, if one side is autoselecting the connection, then the

other side should as well. The settings for the iLO 2 NIC are controlled in the Network Settings screen.

Inability to connect to the iLO 2 Diagnostic Port

If you cannot connect to the iLO 2 Diagnostic Port through the NIC, be aware of the following:

The use of the diagnostic port is automatically sensed when an active network cable is plugged in to
it. When switching between the diagnostic and back ports, allow one minute for the network

switchover to be complete before attempting to connect through the web browser.

If a critical activity is in progress, the diagnostic port cannot be used until the critical activity is
complete. Critical activities include the following:

o

Firmware upgrade

o

Remote Console session

o

SSL initialization

If you are using a client workstation that contains more than one enabled NIC, such as a wireless
card and a network card, a routing issue might prevent you from accessing the diagnostic port. To

resolve this issue:

1.

Have only one active NIC on the client workstation. For example, disable the wireless network card.