Troubleshooting iLO 2 189

Event log display

Event log explanation

iLO 2 Self Test Error: #

Displays when iLO 2 has failed an internal test. The
probable cause is that a critical component has

failed. Further use of iLO 2 on this server is not
recommended.

iLO 2 reset

Displays when iLO 2 is reset.

On-board clock set; was #:#:#:#:#:#

Displays when the onboard clock is set.

Server logged critical error(s)

Displays when the server logs critical errors.

Event log cleared by: User

Displays when a user clears the event log.

iLO 2 reset to factory defaults

Displays when iLO 2 is reset to the default settings.

iLO 2 ROM upgrade to #

Displays when the ROM has been upgraded.

iLO 2 reset for ROM upgrade

Displays when iLO 2 is reset for the ROM upgrade.

iLO 2 reset by user diagnostics

Displays when iLO 2 is reset by user diagnostics.

Power restored to iLO 2

Displays when the power is restored to iLO 2.

iLO 2 reset by watchdog

Displays when an error has occurred in iLO 2 and
iLO 2 has reset itself. If this problem persists, call

customer support.

iLO 2 reset by host

Displays when the server resets iLO 2.

Recoverable iLO 2 error, code #

Displays when a non-critical error has occurred in
iLO 2 and iLO 2 has reset itself. If this problem

persists, call customer support.

SNMP trap delivery failure: IP address

Displays when the SMNP trap does not connect to
the specified IP address.

Test SNMP trap alert failed for: IP address

Displays when the SNMP trap does not connect to
the specified IP address.

Power outage SNMP trap alert failed for: IP
address

Displays when the SNMP trap does not connect to
the specified IP address.

Server reset SNMP trap alert failed for: IP

address

Displays when the SNMP trap does not connect to

the specified IP address.

Illegal login SNMP trap alert failed for: IP

address

Displays when the SNMP trap does not connect to

the specified IP address.

Diagnostic error SNMP trap alert failed for: IP
address

Displays when the SNMP trap does not connect to
the specified IP address.

Host generated SNMP trap alert failed for: IP
address

Displays when the SNMP trap does not connect to
the specified IP address.

Network resource shortage SNMP trap alert
failed for: IP address

Displays when the SNMP trap does not connect to
the specified IP address.

iLO 2 network link up

Displays when the network is connected to iLO 2.

iLO 2 network link down

Displays when the network is not connected to iLO

2.

iLO 2 Firmware upgrade started by: User

Displays when a user starts a firmware upgrade.