Snmp generated trap definitions, Configuring insight manager integration – HP Integrated Lights-Out User Manual

Page 69

Advertising
background image

Configuring iLO 2 69

3.

After generating the alert, a confirmation screen appears.

4.

Check the HP SIM console for receipt of the trap.

SNMP generated trap definitions

You can generate the following SNMP traps on BL c-Class servers and iLO 2:

ALERT_TEST is used to verify that the SNMP configuration, client SNMP console, and network are
operating correctly. You can use the iLO 2 interface to generate this alert to verify receipt of the alert

at the SNMP console. You can also generate this alert using the iLO 2 Option ROM to verify SNMP

configuration settings.

ALERT_SERVER_POWER occurs when the iLO 2 management processor detects an unexpected

transition of the host system power, either from ON to OFF, or OFF to ON. Transitions of the host
system power are unexpected when the change takes place because of events unknown to the

management processor. This alert is not generated when the system is powered up or down using

the iLO 2 interface, CLI, RIBCL or other management feature. If the server is powered down because

of the operating system, physical power button presses, or other methods, the alert is generated and

sent.

ALERT_SERVER_RESET occurs when the iLO 2 management processor is used to perform a cold boot

or warm boot of the host system. This alert is also sent when the iLO 2 management processor
detects the host system is in reset because of events unknown to the management processor. Certain

operating system behavior or actions can cause this type of event to be detected, and the alert

transmitted.

ALERT_ILLEGAL_LOGIN is an SNMP alert transmitted when a connection is attempted using an
invalid username and password. This alert is transmitted regardless of connection type; web

interface, serial port, telnet, SSH, or RIBCL.

ALERT_LOGS_FULL is an SNMP alert transmitted when the iLO 2 Event Log is full and an attempt to

log a new event occurs.

ALERT_SELFTEST_FAILURE is an SNMP alert transmitted when iLO 2 detects an error in any one of

the monitored internal components. If an error is detected an SNMP alert is transmitted.

ALERT_SECURITY_ENABLED alert is transmitted when the iLO 2 management processor detects a

change in the Security Override Switch to enabled.

ALERT_SECURITY_DISABLED alert is transmitted when the iLO 2 management processor detects a

change in the Security Override Switch to disabled.

ALERT_HOST_GENERATED alert is generated when the iLO 2 management processor was asked to

transmit a Host (SNMP passthrough) alert and the management processor was unable to transmit the
original SNMP alert. iLO 2 attempts to transmit this generic alert in order to notify the SNMP

management console that an alert intended to be transmitted from the host system was not

transmitted.

Configuring Insight Manager integration

The Insight Manager Web Agent URL (DNS name or IP address) sets the browser destination of the Insight

Agent link on iLO 2 pages. Typically, this link is the IP address or DNS name of the management agent

running on the host server operating system.