Parameter

Default value Descriptions

Lights-Out
Functionality

Enabled

This setting enables connection to iLO 2. If disabled, all
connections to iLO 2 are prevented.
The iLO 2 10/100 network and communications with
operating system drivers are turned off if Lights-Out

functionality is disabled. The iLO 2 Diagnostic Port for an HP

ProLiant BL p Class server is also disabled.
If iLO 2 functionality is disabled (including the iLO 2

Diagnostic Port), you must use the server's Security Override
Switch to enable iLO 2. See your server documentation to

locate the Security Override Switch and set it to override.

Power up the server and use the iLO 2 RBSU to set Lights-Out

Functionality to Enabled.

iLO 2 ROM-Based

Setup Utility

Enabled

This setting enables or disables the iLO 2 ROM-Based Setup

Utility. Normally, the iLO2 Option ROM prompts you to press
F8 to enter RBSU, but if iLO 2 is disabled or iLO 2 RBSU is

disabled, the RBSU prompt is bypassed.

Require Login for iLO
2 RBSU

Disabled

This setting enables RBSU access with or without a user-
credentials challenge. If this setting is Enabled, and you press

F8 during POST to enter iLO 2 RBSU, a login dialog box
appears.

Show iLO 2 during
POST

Disabled

This setting enables the display of the iLO 2 network IP
address during the host server POST process.

Serial Command Line
Interface Status

Enabled-
Authentication

Required

This setting enables you to change the login model of the CLI
feature through the serial port. The following settings are

valid:

Enabled—Authentication Required

Enabled—No Authentication

Disabled

Serial Command Line
Interface Speed

9600

This setting enables you to use the serial port to change the
speed of the serial port for the CLI feature. The following

speeds (in bits/s) are valid: 9600, 19200, 38400, 57600,
and 115200. The serial port configuration must be set to No

parity, 8 data bits, and 1 stop bit (N/8/1) for proper

operation. The serial port speed that is set by this parameter
must match the speed of the serial port set in the System ROM

RBSU setup.

Minimum Password
Length

8

This setting specifies the minimum number of characters
allowed when a user password is set or changed. The

character length can be set at a value from 0 to 39.