Insertion process with dell equallogic dsm – HP MPX200 Multifunction Router User Manual

Page 163

Advertising
background image

4.

Perform discovery again from the host to one iSCSI ports on each of the router blades. Ensure
that the iSCSI presented target is listed on the Target's property page of the Microsoft iSCSI
initiator.

5.

From Blade 1, log in or connect to the presented target.

6.

Select the Enable multi-path option, and then verify that two paths are visible for the LUN.
Because the default load balancing policy for the Microsoft iSCSI initiator is round robin,
traffic is distributed between the direct path and the blade 1 path.

7.

Disconnect or log out from the direct path.
The I/Os should fail over from the direct path to the Blade1 path.

8.

Using Iometer, verify that the I/Os have not stopped.

9.

Issue the show perf byte command, see

“show perf byte” (page 130)

to ensure that blade1

I/Os are going through the router.

10. From Blade 2, log in or connect to the presented target. The traffic should now be evenly

divided between Blade1 and Blade2.

Insertion process with Dell EqualLogic DSM

Follow these steps to insert the router iSCSI paths with the Dell EqualLogic DSM on Windows Server
2008:1.2.
1.

Install the Dell EqualLogic DSM for your OS. Refer to the HIT Installation and User’s Guide for
instructions.

2.

On the Windows Server 2008, follow these steps to perform remote setup:
a.

Start the setup for DSM.

b.

Accept the terms of the license agreement.

c.

Select the typical installation mode.

d.

Click Install to start the installation.

e.

When prompted, reboot the host. After the reboot, Remote Setup Wizard starts
automatically.

f.

Select the following in the Remote Setup Wizard:

1.

Subnets included for MPIO (the subnet dedicated for iSCSI traffic).

2.

Subnets excluded from MPIO (the management subnet).

3.

Default load balancing policy (least queue depth). This policy compensates for uneven
loads by distributing proportionately more IO requests to lightly loaded processing
paths).

4.

Maintain default settings for the following parameters, unless you are an advanced
user:
a.

Max sessions per volume slice

b.

Max sessions per entire volume

c.

Minimum adapter speed

d.

Use MPIO for snapshots

e.

Use IPv4 or IPv6.

3.

Repeat the steps listed in

“Insertion process with Microsoft MPIO” (page 162)

. However, in

Step 6

you do not need to select the Enable multi-path option, because the Dell EqualLogic

DSM is automatically chosen for MPIO.

Insertion process with Dell EqualLogic DSM 163