LED Startup Sequence

On power up, Commander will go through a boot process. The front panel LED’s will display
different colors and states as Commander goes through these steps. The following is the normal
sequencing of these LED’s after power is applied:

1) Power LED green: power is applied.

2) The Status LED will alternate between Amber and Green as several boot process occur and

will remain Green when completed:

Kernel is loaded and initialized
Reading real-time clock time
Initializing ramdisk and mounting flash file systems,
Loading the CPU lm85 drivers, and MAC address,

3) Serial Port A

Amber: Ready for reset to factor default.
LED will remain on for 30 seconds to permit reset function.

4) Serial Port B

Off normally. Amber if reset button pressed,
If reset button is pressed longer than two seconds, both Serial Port A and Serial Port B
LED’s will turn off and the system will reset to factor default values.

5) The Status LED will alternate between Amber and Green as the boot process continues:

Set up variables including untar web pages, zone files
Setup IP network:

6) The Sensor Status LED will then indicate the final boot steps and will remain off when

complete:

Starting send mail, SSHD, and read probe data.
Mounting NFS if applicable,
Creating new database files and starting database server,
Starting web, ftp, and SNMP servers,