Troubleshooting system does not power-up – Anritsu 373XXA User Manual

Page 59

Advertising
background image

Step 2.

Remove bottom panel, and lay the system down on its left
(monitor) side. Refer to Chapter 8, Remove and Replace
Procedures.

Step 3.

Reconnect the power line input cord to the system and
Press the 373XXA Power key on.

Step 4.

Using a DMM or an oscilloscope, measure the DC power
supply voltages listed in Table 5-1. Connect the
DMM/oscilloscope to the top of the cable connectors at J13
and J4 on the Motherboard (A17). Refer to Figure 5-1 and
Table 5-1.

TROUBLESHOOTING

SYSTEM DOES NOT POWER-UP

373XXA MM

5-5

Connect To:

DC Supply Voltage

AC Ripple and

Noise

Conn Com (Pin) Meas (Pin)

J13

8

16

0 Vdc

50 mVpp

J13

8

1

+4.8 Vdc

+1% / –0%

50 mVpp

J4

4

1

+9 Vdc

+5% / –0%

100 mVpp

J4

4

6

+18 Vdc

+10% / –0%

100 mVpp

J4

4

10

–18 Vdc

+10% / –0%

100 mVpp

J4

4

12

+27 Vdc

+5% / –0%

100 mVpp

J4

4

14

–27 Vdc

+5% / –0%

100 mVpp

Table 5-1. 373XXA DC Power Supply Voltage Checks

J13

J4

1

1

14

16

372XXA A17 Motherboard

D38517-3

(shown upside down)

Figure 5-1. Location of Connectors for Power Supply Voltage Checks

Advertising