Viewing system status, System status data, Viewing system status -17 – Adaptec ANA-62000 User Manual

Page 153: System status data -17, Adaptec nic model number, 17 duralink64 port aggregation for netware

Advertising
background image

11-17

Duralink64 Port Aggregation for NetWare

Viewing System Status

Once you have installed Duralink64 Port Aggregation using lbsetsf,
you can view the system status in the System Status screen. This pro-
gram opens automatically whenever you restart the server.

To manually enter the Status screen, at the system console
prompt type:

load status

Figure 11-30. Data sample provided in the System Status
screen.

System Status Data

Adaptec NIC model number

Total Kilobits/second (Kbps) transmitted per port (stand-alone
and group). Total Kbps transmitted per group. The Kbps sum
of aggregated ports in a group equals the total Kbps
transmitted by their group.

Duralink64 Port Aggregation Status 4.2

< F1> Help

Netware Loadable Module

Groups/Ports

<ESC> to Exit.

© Copyright 1998

,

Adaptec Inc.

Adptsf7
Adptsf8

NIC

Transmit Kbps

Load Perc.

Status

Adptsf4

ANA-62044

10234

100

ACTIVE

Adptsf5

ANA-62044

0

0

DOWN

Adptsf6

ANA-62044

12367

100

ACTIVE

ANA-62044

10151

100

ACTIVE

ANA-62044

8305

100

ACTIVE

Marcom G
Adptsf1
Adptsf2
Adptsf3

ANA-62044

5798

100

ACTIVE

ANA-62044

0

IDLE

ANA-62044

0

DOWN

5798

0
0

100

<F8> Refresh Interval

Server Name -->

[NAME]

Advertising