Restarting the Probe

94

Selecting the Warm Start Menu Item

Use the following procedure to warm start the probe using the probe’s Main
Menu:

1. Connect a local terminal (or a PC emulating a terminal) to the probe. Refer

to “Local Terminal Configuration and Installation” on page 4 for
information on connecting a local terminal.

2. Press the CONFIG button once (on the back of the probe) to place the probe

into the configuration mode. Use a narrow, pointed object (like a pen) to
press the recessed CONFIG button. The probe then displays its Main Menu
on the terminal. Figure 5-1 shows the probe’s Main Menu.

3. Press

7

to execute a warm start and exit the probe’s Main Menu. The warm

start occurs immediately. The Activity and Fault LEDs are turned on during
a warm start. When the warm start completes, the Activity LED flashes to
indicate traffic (if present), the Fault LED turns off, and the ~Line On (or
Power) LED is on.

Main Menu - Revision

1.Modify/View configuration values ->

2.Modify/View security values ->

3.Modify/View interface values ->

4.Display interface summary

5.TFTP Download new firmware ->

6.XMODEM Download new firmware ->

7.Warm start and Exit

8.Cold start and Exit

Figure 5-1: Probe Main Menu