Agilent Technologies HSSI WanProbe J3916A User Manual

Page 131

Advertising
background image

Download New Firmware

Xmodem Download of Firmware

111

If you are using an HP workstation and the probe takes more than 90 seconds to
download new firmware and to restart (boot), verify that the workstation is setup
correctly, and restart

inetd

by entering and running the following commands at

the workstation:

ps -ef | grep inetd

/etc/inetd -k

/etc/inetd

NOTE

If you are experiencing tftp transfer timeouts or read errors, use the following
procedure to verify that tftp is configured correctly on your workstation.

1. Verify tftp functionality by copying the firmware file to another directory
using the tftp command.

# cd /tmp
tftp 127.0.0.1
get firmware
quit

2. If the previous step fails, the problem is due to the tftp configuration on the
workstation.

Advertising