Installation
Connecting the Probe

64

Verify that the Modem Init String is properly initialized for the attached modem
by referencing the modem’s documentation. The probe’s default modem
initialization string is configured to work with low-speed and medium-speed
Hayes compatible modems. The following modem settings are recommended for
low-speed to medium-speed modem connections:

Modem Flow Control:

Off

Data Compression (if applicable):

Off

Error Correction (if applicable):

Off

Not all Hayes commands are the same for all Hayes-compatible modems. Refer
to your modem’s documentation to determine the commands required for each of
the above settings and append these commands to the end of the default Modem
Init String
.

NOTE

Your modem documentation discusses the features that are relevant to your
modem. If your modem does not support a feature (data compression, for
example), you do not need to turn it off in the Modem Init String.

Some modems require you to set register values explicitly, rather than sending
Hayes style commands. In this case, follow your modem documentation to set
these registers.

If you are using a high-speed modem, you probably need to modify the default
modem initialization string. The following modem settings are recommended for
high-speed modem connections:

Modem Flow Control:

Hardware Flow Control (RTS/CTS signaling)

Carrier Detect:

Always On

Data Compression:

Enabled

Error Correction:

Enabled

After appending the appropriate commands to the modem initialization string,
warm start your probe.

Refer to your NetMetrix documentation for information on how to establish
communications with the probe over the SLIP link.