Local Terminal Configuration
Using the Main Menu

20

4. Start the configuration by quickly pressing the CONFIG button on the back

of the probe one time only. After about 10 seconds, the probe displays its
Main Menu on the terminal. Figure 2-1 shows the location of the CONFIG
button and Figure 2-2 on page 21 shows the probe’s Main Menu. If the Main
Menu is not displayed, verify that the previous steps in this procedure have
been performed correctly.

NOTE

The probe CONFIG button is recessed. This requires the use of a narrow, pointed
object (like a pen) to press the CONFIG button.

The probe executes a cold start if you press the CONFIG button twice within one
second. If this happens, wait for the cold start to be completed and press the
CONFIG button again to enter the configuration mode.

A warm start or cold start is completed when the Fault LED goes off. If traffic is
present, the Activity LED flashes to show traffic.

Figure 2-1: Probe Rear Panel