Selecting the cold start menu item – Agilent Technologies HSSI WanProbe J3916A User Manual

Page 116

Advertising
background image

Probe Operation
Restarting the Probe

96

Selecting the Cold Start Menu Item

Use the following procedure to cold start the probe using the probe’s Main Menu:

1. Connect a local terminal (or a PC emulation a terminal) to the probe. Refer

to “Probe Operation” on page 89 for information on connecting a local
terminal.

2. Press the CONFIG button once (on the back of the probe) to place the probe

into the configuration mode. Use a narrow, pointed object (like a pen) to
press the recessed CONFIG button. The probe then displays its Main Menu
on the terminal. Figure 5-1 on page 94 shows the probe’s Main Menu.

3. Press

8

to execute a cold start and to exit the probe’s Main Menu. The cold

start occurs immediately. The Activity and Fault LEDs are turned on during
a cold start. When the cold start completes, the Activity LED flashes to
indicate traffic (if present), the Fault LED turns off, and the ~Line On (or
Power) LED is on.