Agilent Technologies HSSI WanProbe J3916A User Manual

Page 54

Advertising
background image

Local Terminal Configuration
Using the Main Menu

34

Port

Press

1

and then type the HSSI WAN interface port number

to display the HSSI WAN port configuration parameters
along with their current settings. Refer to “Display Interface
Summary” on page 36
for information on port types and port
numbers for the installed interfaces. You can then view or
configure the HSSI WAN port’s configuration parameters.
The following are your HSSI port choices:

z

[3] 3.1/Frame_Relay

z

[4] 3.1/HSSI

Port Type

The port type is set to Monitor-only.

Data Sense

Press

3

and then select the format of the bit stream (the Data

Sense type) as Normal, Inverted, or NRZI (Non-Return to
Zero Invert, on zeros).

Normal means that the data bits are not inverted or, in other
words, that a Mark represents a binary 1. Inverted means that
the data bits are inverted or, in other words, that a Mark
represents a binary 0. NRZI means that bit timing is
determined from the clocking signals present on the HSSI
interface and successive Marks or Spaces represent a binary 1
and changes from Mark to Space or from Space to Mark
represent a binary 0.

Link Type

Press

4

and then select the link layer analysis type as Frame

Relay, HDLC, SDLC, or PPP.

Advertising