ELITE SERIES USER MANUAL

THEORY OF OPERATION

Motor Off/On

LDA $C088,X

Turn Motor Off

LDA $C089,X

Turn Motor On

N O T E : A delay should be provided to allow the

motor to come up to speed. DOS will keep this

delay to a minimum by watching the read latch

until data starts to change. Motor—on timing

characteristics for the Elite Series drives can

be found elsewhere in this manual.

Engage Drive within Bank

LDA $C08A,X Engage Drive 1:

LDA $C08B,X Engage Drive 2:

P a g e 7 — 2 2