12. Alignment menu

Image 12-51

Image 12-52

12.11.6 ScenergiX overlap zone (vertical ScenergiX)

Definitions

Image 12-53
Scenergix overlap zone vertical

Overlap : number of pixels that overlap

Vertical resolution of 1 projector

Total vertical screen resolution : [(Vertical resolution of 1 projector) x 2] minus (overlap)

Vertical Resolution source : number of active lines of the source

How to set for the first projector

1. Go to Layout Main window Size

2. Enter the value for the Height as follow: Total Vertical screen resolution / 2 - 0.5 x overlap zone.

3. Position remains the same. (image 12-54, image 12-55, image 12-56, image 12-57)

Image 12-54