Dynaflow, User manual - introduction – Ransburg DynaFlow User Manual User Manual

Page 13

Advertising
background image

LN-9400-00.9

DynaFlow

TM

User Manual - Introduction

9

The output of the first Gun is then fed into the

Master Channel input of the second Gun. The

second Gun is setup as follows:

Gun 2 =

Master Channel =

Material = Output of Gun 1 (Resin + 2

nd

Component)

Flow Controller = Color Change Value

(CCV)

(see Notes 1, 2, and 3)

Flow Meter = Gear-Type

Slave Channel =

Material = 3

rd

Component

Flow Controller = MVR, with appropriate

size

needle

Flow Meter = Piston or Gear, depending on

min/max flow rates

(see Notes 4 and 5)

Operating Mode = Manual or Auto

(see Notes 1, 2, and 3)

NOTES:

1. If the output of Gun 2 supplies one or more

hand guns, then Gun 2 should be operated in

Manual mode using a CCV for the Master

Channel flow controller.

2. If the output of Gun 2 supplies a single appli-

cator, then an MVR should be used for the

Master Channel flow controller and Gun 2

should be operated in Auto mode.

3. If the output of Gun 2 supplies multiple appl-

icators other then hand guns, then Gun 2 should

be operated in Manual mode using a CCV for the

Master Channel flow controller. Additional Guns

should be configured for each applicator as shown

below to provide automatic flow control for each

applicator.

Gun 3 through 6 =

Master Channel =

Material = Output of Gun 2 (Resin + 2

nd

+

3

rd

Components)

Flow Controller = DR1

Flow Meter = Gear-Type

Operating Mode = Auto

NOTE

Refer to Addendum C for complete

information regarding the flow limitations of

the DynaFlow Channel cards.

Advertising