Parameter descriptions, Config system (f1), Dynaflow – Ransburg DynaFlow User Manual User Manual

Page 34: User manual - operation

Advertising
background image

LN-9400-00.9

PARAMETER

DESCRIPTIONS

CONFIG SYSTEM (F1)

All system parameters are password protected,

unless disabled by setting the password to zero

(0). Any time an operator wishes to change any

of these parameters, they are prompted for the

password. The password only needs to be entered

once as long as the time between keystrokes does

not exceed the Password Timer as described

below. System parameters may be edited at any

time regardless of the operating mode if no sys-

tem errors exist. Any active system errors must

be cleared.

Horn Code

This is a coded number that represents when the

supervisor would like the System Fault output relay

to energize. This output is normally connected to

a horn. The options desired are selected.

0 = No horn

1 = Horn when controller faults

2 = Horn when pot-life timer has expired

4 = Horn when external fault is detected

Blow Off Time

This parameter is used only if the GUN is config-

ured as a manual GUN. The software monitors

the trigger signal to identify when the spray GUN

is triggered. (Typically this signal comes from an

air flow switch located in the atomization air line.)

If the software ever detects a GUN trigger signal

without pulses from the master channel flow meter

after the ‘Blow Off’ time has elapsed, a No Master

Flow fault is issued. This prevents a painter from

painting if the flow meter sticks. In some manual

Any modifications to the System Pa-

rameters screen data are saved only when

the operator presses the "Store Data" key

(F5), otherwise the modifications will be

lost when the screen is exited with the es-

cape (ESC) key.

NOTE

30

DynaFlow

TM

User Manual - Operation

applications, painters will only trigger the spray

GUN enough to get atomization air to flow without

material. They use this air to blow off or feather

the part. The software would normally sense this

air flow without material flow and then fault the

GUN. This parameter allows the painter a preset

number of seconds of blow off time before faulting.

This parameter is specified in seconds, and the

default is 5 seconds. A setting of zero (0) disables

the no master flow fault.

Change Password (F3)

Used in conjunction with the Password Timer pa-

rameter. The operator can change the password

if the previous password is known. The password

is required for editing or setting all data tables and

configuration parameters. A password of '0' will

disable password operation.

Password Timeout

Once a valid password has been entered, this

parameter sets the amount of time (in min) which

is allowed from the last keystroke until password

operation is stopped. Once the timer has expired,

the user will be prompted for the password again

if password protected settings are to be edited.

RIO Rack Address, Rack Size,

Starting Quarter, and Baud Rate

Displays the RIO communication parameters,

as decoded from the Interface Module DIP SW1

and SW2 settings.

SIO Baud Rate and COM Port

Displays the SIO communication baud rate, as

decoded from the Interface Module DIP SW1

and SW2 settings, and the COM port (COM1 or

COM2), as defined in the GO.INI file.

Channel Module Firmware Revision(s)

Displays the firmware revision for the installed

Channel Modules.

Interface Module Firmware Revision

Displays the firmware revision for the Interface

Module.

User Interface Revision

Displays the current version of the user-interface

software running on the user-interface PC.