Dynaflow, User manual - maintenance, Interface module dip sw2 settings – Ransburg DynaFlow User Manual User Manual

Page 85

Advertising
background image

LN-9400-00.9

81

DynaFlow

TM

User Manual - Maintenance

All data will be lost when

set to ON position.

Number Of Channel

Modules:

1

1 to 3

1 to 4

1 to 4

Position

Description

Comments

1

2

3-4

5-6

7-8

ON = NVRAM Erased & Reset

OFF = NVRAM Maintained

ON = Master Channel outputs Master

Chanel flow rate on secondary

analog output.

OFF = Master Channel outputs GUN flow

rate on secondary analog output.

RIO Baud rate position

3

4

Baud Rate

OFF OFF = 57.6 KB

OFF ON

= 115.2 KB

ON

OFF = 230.4 KB

ON

ON

= 230.4 KB

SIO Baud rate position

5

6

Baud Rate

OFF OFF = 19.2 KB

OFF ON

= 4.8 KB

ON

OFF = 9.6 KB

ON

ON

= 38.4 KB

RIO Rack Size position

7

8

Size

OFF OFF = 1/4 Rack

OFF ON

= 1/2 Rack

ON

OFF = 3/4 Rack

ON

ON

= Full Rack

Default Setting

OFF

OFF

OFF

OFF

OFF

INTERFACE MODULE DIP SW2 SETTINGS

*

Inserting this jumper adds a 120 Ohm termination resistor across the RS-485 RX+ and

RX- lines.

** Inserting this jumper adds a 120 Ohm termination resistor across the Ransburg CAN Bus.