LN-9400-00.9

DYNAFLOW

SPECIFICATIONS

Transducers:

The air supplied to the trans-

ducers must be clean and dry

and meet the following general

specifications:

Filtration:

20 Micron

Supply Pressure:

90 PSIG min. to 150 PSIG

max.

Volume:

0.04 to 0.13 Cv

Operating Temperature:

32

o

to 150

o

F (0

o

to 65.5

o

C)

Dimensions:

83mm H X 250mm W X

184mm D standard half rack

Power Requirements:

24 VDC at 1 Amp typical, all 8

CHANNELs installed

The following must be followed if the flow control

rack and/or Operator Interface is to be integrated

into a larger system control panel:

- The 24 VDC Power Supply must be located in the

same control panel as the fluid flow control.

-

DO NOT use a central power supply located else

where. The power supplies may be sized for and

used for other controls within the same cabinet

WITH THE EXCEPTION OF HIGH VOLT-

AGE POWER SUPPLY CONTROLLERS.

High voltage power supply controllers MUST have

a dedicated power supply.

Pneumatic Requirements

Control Rack (Up to 8 Channels Per

1/2 of 19" Rack)

Interface Module Hardware

Interface Module Hardware (Cont.)

Digital Inputs:

24 VDC at 2.3 ma typical per input

(optically isolated, source by de-

fault, sink selectable)

- JOB Select Strobe

- JOB Select 1 (lower significant

BCD digit)

- JOB Select 2

- JOB Select 4

- JOB Select 8

- JOB Select 10 (middle significant

BCD digit)

- JOB Select 20

- JOB Select 40

- JOB Select 80

- JOB Select 100 (upper significant

BCD digit)

- System Ready/Halt

- Global Gun Enable

Digital Outputs:

24 VDC sourced at 300 ma maxi-

mum per output (Solid state relay

contacts)

System Pulse:

Used as watchdog timer by an

external supervisory PLC or com-

puter.

System Fault:

Used to activate an alarm and to

supply a signal remotely that a

System, GUN, or other fault has

occurred.

Communications

RS-232C Port:

Communication with local

Opperator Interface unit.

Allen-Bradley

RIO Port:

For direct high-speed communi-

cation with Allen-Bradley PLC's.

CAN:

Control Area Network (CAN) high

speed communication with all

channel Modules and with other

racks.

Power Requirement:

24 VDC at 100 ma typical

Operating Temperature:

0

o

to 55

o

C

DynaFlow

TM

User Manual - Introduction

11

General:

This Module is responsible for

local display/keyboard control and

communication to the Host control-

ler. Responsible also for non-vola-

tile storage of all JOB data tables

and system configuration param-

eters.

Dimensions:

3U (130.5 mm) H x 7H

(35.2 m) W standard 19" rack module