Analog Hold mode without causing the fluid

tubes to pressurize to the material supply

pressure while the GUN is not triggered.

For systems with fast trigger cycles or where

dynamic control of fluid flow rates (different

flow rates during a JOB), mount the E/P

transducer as close to the material regulator

as possible. Remember that the transducers

MUST be mounted outside of the hazardous

location (refer to NFPA-70, NEC). For appli-

cations where the requested fluid flow is for

the most part consistent, and transitional re-

sponse time of the system is not as critical,

then the E/P transducers may be located in

the main control panel.

Be sure that stainless steel tubing or piping

and stainless steel fittings are used for all

fluid lines and connections where metal is

desired.

Always mount the flow meter and regula-

tor as close as feasible to the applicator. This

reduces paint line pulsation due to applicator

reciprocators and reduces the possibility of a

paint leak effecting paint delivered to the

part.