LN-9400-00.9

80

DynaFlow

TM

User Manual - Maintenance

0 - 63 Decimal

0 - 77 Octal

0 - 3F Hex

Number of Channel

Cards:

1 to 4

1 to 4

1 to 3

1

Position

Description

Comments

1-6

7-8

RIO Rack address

position 1 = most significant bit (MSB)

position 6 = least significant bit (LSB)

RIO Starting Quarter position

7

8 Quarters

OFF OFF = 0

OFF ON

= 1/4

ON

OFF = 1/2

ON

ON

= 3/4

Default Setting

OFF

Address = 00

OFF

INTERFACE MODULE DIP SW1 SETTINGS

Jumper Description

JMP15 Flow Rate Freq. Input,

Channels A and B

Flowmeter Inputs:

FactorySetting

X

Type

Source

Sink

Pin 1-2

Open

Closed

Pin 2-3

Closed

Open

Jumper Description

JMP16

JMP17

JMP18

UVEPROM

RAM

Processor Pin EA

Memory and Processor Settings:

FactorySetting

X

X

X

Type

256KB

512 KB

1024 KB

8Kx8

16Kx8

32Kx8

Run

Prog.

Pin 1-2

Closed

Open

Open

Open

Closed

Closed

Open

Closed

Pin 2-3

Open

Closed

Closed

Closed

Open

Open

Closed

Open

Ransburg CAN Bus Address

Communication between the Interface Module

and Channel Cards.

The Control Area Network (CAN) address of the

Interface is automatically determined by hardware

based on the physical slot location in the rack.