DynaFlow

TM

User Manual - Operation

29

Parameters

The controlling parameters for each GUN, and for

the CHANNELs assigned to that GUN, are called

JOBs (also commonly referred to as PSETs, Color

Tables or Recipes). The JOB values define flow

characteristics such as TARGET FLOW RATE,

MIX RATIO, FLOW TOLERANCE, etc. JOBs

include all of the parameters that may be depen-

dent on the material used. This offers the ability

to optimize system control as needed per material

and then recall the settings each time that mate-

rial is requested. There are up to 100 JOB #s for

each GUN. By saving frequently used JOB #s to

memory you can later recall them by loading the

number representing that JOB #. The parameters

are viewed and edited through the local Operator

Interface or through a remote host computer.

A set of initial parameter values is included in the

controller. The initial (default) values determine the

operating conditions of the controller when started

for the first time. Some of these will need to be

edited during initial setup based on the installation.

Slave Channel =

Material = 3

rd

Component

Flow Controller = MVR, with appropriate

size needle

Flow Meter = Piston or Gear-Type,

depending on

min/max flow rates

(see Notes 4 and 5)

Operating Mode = Manual or Auto

(see Notes 1, 2, and 3)

NOTES:

1. If the output of Gun 2 supplies one or more

hand guns, then Gun 2 should be operated in

Manual mode using a CCV for the Master Chan-

nel flow controller.

2. If the output of Gun 2 supplies a single appl-

icator, then an MVR should be used for the Mas-

ter Channel flow controller and Gun 2 should be

operated in Auto mode.

3. If the output of Gun 2 supplies multiple appl-

icators other then hand guns, then Gun 2 should

be operated in Manual mode using a CCV for

the Master Channel flow controller. Additional

Guns should be configured for each applicator

as shown

below to provide automatic flow

control for each applicator.

Gun 3 through 6 =

Master Channel =

Material = Output of Gun 2 (Resin + 2

nd

+ 3

rd

Components)

Flow Controller = DR1

Flow Meter = Gear-Type

Operating Mode = Auto

4. Minimum flow rate for the DynaFlow is deter-

mined for each channel based on the number

of pulses/liter for the flow meter for the channel.

(Refer to "Addendum C" for flow limitations.)