LN-9400-00.9

Channel Module Hardware Specifi-

cations (Cont.)

DynaFlow

TM

User Manual - Introduction

13

FLOW RATE JOB parameters)

4 Frequency Inputs:

From flow meters (reverse

flow capable)

Source Signal #1 & #2:

Frequency used to determine

flow rate (pulses per volume or

weight).

Maximum Frequency = 435 Hz

Minimum Frequency = 1 Hz

(Refer to Addendum C for flow limitations.)

Phase Signal #1 & #2: State used to determine

direction of flow rate, forward or

reverse.

PID Control:

Closed loop control based on

the Kp, Ki, Kd and deadband

JOB parameters. 30ms PID up

date time (default), each chan-

nel.

Communications

CAN:

Controller Area Network (CAN) High-

speed serial communications to In-

terface Module.

RS-232C Port:

Spare auxiliary communication port.

Power Requirements:

24 VDC at 100 ma

typical – each Channel Module

Operating

Temperature:

0

o

to 55

o

C

Interface Enclosure (A12182)

Dimensions:

610mm H X 610mm W X 410mm D

Weight:

22.7 Kg (50 lbs)

Temperature:

5°C - 40° C

Humidity:

80% to 31° C decreasing to 50% at

40° C non-condensing

Control Enclosure (A12233)

Dimensions:

610mm H X 610mm W X 410mm D

Weight:

45.5 Kg (100 lbs)

AC Power:

115/230 VAC, 3A

50/60

HZ

1

Phase

Temperature:

5°C - 40° C

Humidity:

80% to 31° C decreasing to 50% at

40° C non-condensing