LN-9400-00.9

DynaFlow

TM

User Manual - Maintenance

66

Displayed Text

Fault Cause

Corrective Action

Code

B010

(Cont.)

B020

B030

B040

B050

B060

RIO - Communi-

cations Error

(Cont.)

RIO - Invalid

BTW Type

RIO - Invalid

BTR Type

Gun/Channel

Number

RIO - Invalid

BTR Job

Number

RIO - Invalid

BTW Length

RIO cable is not properly

terminated at each end.

The PLC has issured a BTW with

an invalid BTW data type in the first

word offset.

The PLC has issued a BTW with an

invalid BTR data type in the second

word offset.

The PLC has issued a BTW with

an invalid gun or channel number

in the third word offset.

The PLC has issued a BTW with

an invalid job number in the fourth

word offset.

The PLC has issued a BTW with an

invalid message length (word count).

Check cable connections per Figure 25

of this manual.

Check each end of the cable to de-

termine if the terminating resistor is

installed at each end. The DynaFlow

system may not be the last rack on the

RIO cable. The value of the terminating

resistor is based on cable length, baud

rate, and if Extended Node Capability is

enabled at the PLC. If Extended Node

Capability is enabled, the terminating

resistors should always be 82 ohms.

Otherwise, the term-inating resistors

should be 150 ohms for 57.6 and 115.2

Kbaud and 82 ohms for 230.4 Kbaud.

In any case, use

1/2 watt resistors.

Have the PLC programmer reference

the "DynaFlow Programmer" manual

for the correct BTW data types.

Have the PLC programmer reference

the "DynaFlow Programmer" manual

for the correct BTR data types.

Have the PLC programmer ensure gun

and channel numbers are between 1 and

8, or 0 if not required for the particular

data type.

Have the PLC programmer ensure job

numbers are between 1 and 100, or 0 if

not required for the particular data type.

Have the PLC programmer reference

the "DynaFlow Programmer" manual

for the correct BTW message lengths.

ERROR CODES (Cont.)