Dynaflow, User manual - operation, Config gun (f2) – Ransburg DynaFlow User Manual User Manual

Page 35

Advertising
background image

LN-9400-00.9

DynaFlow

TM

User Manual - Operation

31

CONFIG GUN (F2)

GUN Configuration Parameters should

not be

edited while the GUN is running. This includes
all operational modes.

System Time and Date

Displays the current date and time and permits

changing the same.

Language

This allows users to select between English and

one Alternate Language. The alternate language

text is stored on the flash drive or hard drive of

the PC in files named: TEXTMESS_ALT.TXT,

PARAMHLP_ALT.TXT, LABELS_ALT.TXT, SO-

LENOIDVALVES_ALT.TXT, and

HELP_ALT.TXT.

Channel Module DIP SW1 Settings

Displays the DIP SW1 settings for each installed

Channel Module.

Interface Module DIP SW1 and SW2 Set-

tings

Displays the DIP SW1 and SW2 settings for the

Interface Module.

- Mode

This parameter has three possible settings: OFF,

AUTO, and MANUAL.

OFF - This setting completely disables the gun,

removes its data from the main screen, and places

the channels tied to the gun available for use by

another gun.

AUTO - This setting is used when the user wants

to control both the flow rate and the ratio (if it is

a plural component material) of the applicator.

Any modifications to the GUN Config-

uration Parameters screen data are saved

only when the operator presses the "Store

Data" key (F5), otherwise the modifica-

tions will be lost when the screen is exited

with the escape (ESC) key.

NOTE

MANUAL - This setting is used when the user

wishes only to control the ratio of the material.

Users can 'demand' as much material as they wish

and the controller will deliver as much as possible

while keeping the ratio on target.

- Number of Channels

This parameter has three possible settings: 0,

1, and 2.

0 - This, effectively, disables the gun.

1 - This indicates that the gun is to be a single

channel, flow control only applicator.

2 - This indicates that the gun is to be configured

as a dual-channel, ratio controlled applicator.

- Master Channel

This parameter has eight possible settings: 1-8.

For single channel guns, it simply indicates which

channel will be controlling the flow control valve

and reading the flowmeter for this applicator.

For dual-channel guns, this indicates (normally)

which channel will be controlling the resin part of

the mixed material. It is always desirable for the

master channel to have the higher flow rate of the

two materials.

- Slave Channel

This parameter has four possible values: 2, 4,

6, or 8.

It indicates which channel will be the slave (typi-

cally the catalyst) to the master channel (selected

above) for ratio control.

- Clean Channels

This parameter has four possible values: NONE,

MASTER, SLAVE, or BOTH.

This setting determines which of the fluid regula-

tors (or MVR valves) are opened to full when the

unit is put in 'Clean Mode' for flushing and filling

operations.

Default JOB#

Sets the JOB# which is loaded at power ON.